FLOW PATTERNS
 
2-Way Normally Closed. In the "De-energized" state media enters the valve through the In Port and is held until the coil is "Energized" allowing the media to exit through the Out port. This is the most common flow pattern.

 
2-Way Normally Open. In the De-energized state the media is allowed to travel through the valve In Port and exit at the top through the Out Port. In the energized state media flow is st

 
3-Way Normally Closed. In the de-energized state media entering through the In Port is held while media from the Cylinder Port is allowed to exit through the Exhaust Port. When energized the In Port media travels through and exits at the Cylinder Port and the Exhaust Port is closed. Typical uses for this flow pattern are air cylinder applications.

 
3-Way Normally Open. When de-energized media flows from the top In Port through to the Cylinder Port. In the energized state media flows Back through the Cylinder Port and exits at the Exhaust Port and the In Port is closed.

 
Diverting. In the de-energized state media flows from the In Port through the Out NO port at the top. When energized media flows to the Out NC port and the Out NO Port is closed. This allows a single media to be directed to two different applications.

 
Selector. In the de-energized state media flows from the IN NO Port to the Out Port. When energized the media from the IN NO Port is blocked and the media from the In NC Port is allowed to flow to the Out Port. This flow pattern can be used to select from two different media types and output to one application.